Introduction:
|
Kapton tape is used during the initial installation
and process qualification of ST Systems etch tools by the install
engineer. The tape has later been used in micro-engine processes
for:
- Covering global alignment marks in AX9260 since thick resist
may form bubbles if painted on, resulting in pox and through
holes in the wafers
- Backside seal when through holes and uniform etch are needed
at the same time.
The tape must be applied to the wafer Using tweezers to avoid getting
fingermarks on the wafer surface. The tape can be removed easily
if it is put on top of resist and released in Acetone. When
put directly on wafer surface, tape residue is difficult to remove
by the usual cleaning processes such as Ashing, Piranha, and RCA.
|
Procedure:
|
Process 1: Backside Sealing
- Perform Photolithographic process on the front side.
- Coat the wafer with thick resist on the back side and bake. Inspect
to make sure the area to be taped is fully covered.
- Put Kapton tape on the backside. Ensure that there are
no bubbles and the contact is good.
- DRIE in one of the STS machines according to process flow.
- Place the wafer in a plasti000 c beaker with Acetone until
all tape peels off the wafer. Peel the tape off before
putting the wafer in acetone if possible.
- Thorough rinse the wafer with solvents, inspect for tape residue.
- Continue with normal cleaning procedures: Piranha, Ashing,
and/or RCA depending on regular process flow. There should
be no tape or its residue in the Asher, Piranha, or RCA.
Process 2: Alignment Marks
- Complete Photolithographic process with AZ9260.
- Paint the alignment marks or other features with thick resist
and bake
- Cover the painted area with Kapton tape. Ensure that
there are no bubbles and the contact is good.
- DRIE in one of the STS machines according to process flow.
- Place the wafer in a plastic beaker with Acetone until all
tape peels off the wafer. Peel the tape off before putting
the wafer in acetone if possible.
- Thorough rinse the wafer with solvents, inspect for tape residue.
- Continue with normal cleaning procedures: Piranha, Ashing,
and/or RCA depending on regular process flow. There should
be no tape or its residue in the Asher, Piranha, or RCA.
|