Introduction:
|
The AME 5000 is a Radio Frequency (RF) magnetically coupled etching
system. This system is configured with two etch chambers. The chamber
designations are chamber A and chamber B. Chamber A is dedicated
to etching Thermal Oxide, Low Temperature Oxide (LTO) and Boron
Phosphorus Silicate Glass (BPSG)and Silicon Nitride. The gas chemistries
supplied to chamber A are Oxygen (O2), Halocarbon 14
(CF4) Halocarbon 23 (CHF3). Chamber B is primarily used
for Silicon etching. Howwever, Chamber is used as a backup for the
nitride etching with a SF6 nitride recipe. Chamber B is capable
of etching Silicon trench, UN-doped Polysilicon, Doped Polysilicon
and Silicon Nitride. Gas chemistries supplied to chamber B are Chlorine
(Cl2), Hydrogen Bromide (HBr), Oxygen (O2), Sulfur Hexafluoride
(SF6), and Nitrogen Trifluoride (NF3).
The system is completely controlled by a computer, and wafers
are transported via robotic arm movement. The samples are mechanically
clamped onto the chamber electrode to prevent movement during process.
Helium backside cooling is provided for the purpose of keeping the
wafer at a uniform temperature and of preventing photoresist from
burning.
Two loading zones are supplied on the system, which allows the
wafers to be loaded in a cassette to cassette mode and places the
wafer in the exact cassette slot after processing is completed.
The system can be run in the manual or automatic mode. The process
program can be written so wafer processing can be performed sequentially.
There is a load lock system which enables you to transfer wafer
from the load lock in parts of eight wafers, and perform all processing
and load lock to chamber transfer without breaking vacuum. The cassette
to chamber transfer is accomplished in the following manner.
For a 25-wafer lot process,
- The cassette is placed onto the loading platform.
- The robotic arm removes 8 wafers from the cassette on the loading
platform and places them on a load lock storage elevator.
- From the load lock storage arm, they are transfered to a specified
chamber, chamber A or chamber B.
- After the process is performed on the first wafer, it is then
returned to the load lock elevator and the second wafer is taken
into the chamber.
- The wafers are removed from and replaced back into the same
slot.
- When all the wafers are processed, the load lock comes up to
atmosphere and the first eight wafers are returned to the original
cassette slot and the next eight wafer go through the same cycle
until all the wafers are processed.
|
Procedure:
|
NOTE: It is MANDATORY to RESERVE the system prior to use. It is
mandatory to ENGAGE MACHINE prior to starting your process in CORAL.
- If operating in manual mode, one must perform a HOME ALL ROBOTS.
If operating in the automatic mode, the system will perform the
HOME ALL ROBOTS prior to loading wafers.
- Select the process RECIPE icon. With the lite pen click onto
the recipe icon at the top of the screen. This page contains all
the recipes applicable on the system.
- Change the time parameter in the recipe according to the thickness
of the material to be etched. This system does not have endpoint
detection. NOTE: Chamber A for Oxide and Nitride. Chamber B for
Silicon, Polysilicon and Nitride.
- Click onto the CONTROL icon at the top of the screen. The recipe
that is being used must appear in the proper chamber. Look at
the chamber designation near the bottom of the screen, click on
either chamber A or chamber B. A window will appear in the center
of the screen, with the lite pen, select the desired recipe. The
recipe will be automatically loaded for the selected process chamber.
Processing wafers in the AUTOMATIC mode:
- Click on WAFER with the lite pen. Click on MONITOR WAFER.
- When the window appears on the screen, click on SHUTTLE CASSETTE
to move the cassettes to the proper place on the cassette loading
station.
- Place the cassette containing the wafers to be processed onto
the loading station and be sure that the locating pins on the
cassette align with the locating pins on the system. If they are
not aligned, the the system will alarm and retry the alignment.
- On the bottom of the same screen, select clamp cassette. CLAMP
A or CLAMP B, whichever applies.
- Click on CONTROL located on the top of the screen. When the
window appears, click on the MANUAL. A small screen will appear
below the MANUAL prompt. Click on the AUTOMATIC prompt with the
lite pen.
- Click on the WAFER prompt. When the selection window appears,
click on RUN (GO) BUTTON. The other option is to press the START
button on the front of the system near the cassette load shuttle.
The shuttle cassette door will close. NOTE: The first 8 wafers
will be transfered onto the load lock elevator and into the process
chamber. After these wafers are processed, they will be placed
back into the cassette in the order in which they were removed.
Then the next wafers will be transfered onto the storage elevator
for processing. This system will process a maximum of 25 wafers.
- After all the wafers have been processed, press the unload push
bottom on the front of the system and the shuttle cassette door
will open.
- Click on WAFER (if not already on the proper screen). When the
window appears, click on MONITOR WAFER.
- Click on RELEASE A or RELEASE B, whichever applies. Remove the
cassette and wafers.
- DISENGAGE MACHINE in CORAL.
Processing wafers in the MANUAL mode:
For small wafer lots, this procedure may be a better option.
- Click on WAFER with the lite pen. Click on CONTROL HANDLER.
When window changes, click on HOME ALL ROBOT AXIS. A window will
appear. Click on HOME ALL ROBOT AXIS. This cycle should take a
few minutes. It is important to perform this robotic function.
If not, the robot may loose its location and will not fully transfer
wafers.
- Click on WAFER with the lite pen. Click on MONITOR WAFER.
- When the window appears on the screen, click on SHUTTLE CASSETTE
to move the cassette to the proper place on the cassette loading
station.
- Place the cassette containing the wafers to be processed on
to the loading station, be sure that the locating pins on the
cassette align with the locating pins on the system. If they do
not align, the the system will alarm and retry the alignment.
- At the bottom of the same screen, select clamp cassette. CLAMP
A or CLAMP B, whichever cassette is in place.
- Click on CONTROL located on the top of the screen. When the
window appears, it should be in MANUAL at SYSTEM STATE. If the
system is no in MANUAL, click on the AUTOMATIC. When a small window
will appear, click on MANUAL. Now the system is in the MANUAL
mode.
- Click on WAFER. When a window appears, click on MONITOR WAFER.
This gives a graphic display
- Place the cassette on the shuttle cassette loading station.
Be sure the cassette alignment locations pins are aligned. If
the cassette is not properly aligned, the system will alarm when
clamping the cassette.
- On the same page, click on CLAMP A or CLAMP B. If system goes
into an alarm, click on RELEASE and re-align the cassette and
CLAMP the cassette again.
- Notice that, when the wafers are clamped, the graphics will
display a series of dotted line (vertically) that represents 25
wafers in a cassette. If you choose to you may delete as many
slots as you want. Click on the first wafer you want to delete.
A window will appear. Click on the prompt START DELETE RANGE.
Click on the last wafer for deletion and click on END OF DELETE
RANGE. All wafer slots in between the first and the last wafer
slot depicted on the screen will be deleted.
- Now you are ready to transport wafer to and from the load station
cassette to the etch chamber. With the lite pen, click on the
wafer you want to transport. A window will appear on the screen.
Click on SOURCE FOR MOVE. Click on the dash line depicted in the
chamber you are processing in. When a window comes up on the screen,
click on DESTINATION FOR MOVE. This will transport thewafer to
the chamber.
- Once the wafer is loaded into the etch chamber, select CONTROL
icon. Click on the etch chamber of your choice and verify that
your recipe has been down loaded. If it has not been down loaded,
click on the chamber and select the recipe from the list that
appears on the screen. Select the chamber by clicking (PROCESS
IN CHAMBER) CHAMBER A or CHAMBER B.
- On the same page opposite the selected chamber, click on the
RUN prompt.
CAUTION: Do not strike plasma in any chamber without a
wafer present. If a wafer is not present and a plasma is struck,
it will burn the wafer lifter tips and the seals for helium backside
cooling.
- When the etch is complete, click on the chamber where the wafer
is. When a window appears on the screen, select the prompt SOURCE
FOR MOVE. Click on the cassette wafer slot you want to place the
wafer. When a window appears, click on destination for move. This
will transfer the wafer back into the cassette.
- Click on RELEASE A or RELEASE B whichever applies.
- Remove the cassette and wafers.