<\/a><\/p>\n"},"caption":{"rendered":"Figure 2: a. Fluorescence image of nanodiamonds over a 35×35\u03bcm2 area. Gold `+’ markings indicate sites with ESR modulation; blue `x’s show no modulation. b. Reconstructed region from (a.) after applying DESM technique; blue circles indicate lack of ESR modulation. Using ESR spectrum at each site and DESM technique, we reconstruct multi-emitter sites over a 7×9\u03bcm2 field of view. Numbers correspond to resonance frequencies of each NV- center in site. c. ESR spectrum of a multi-spectral site from (b.). Colored Lorentzian fits correspond to resonances of all four NV- centers in site. d. Sub-diffraction limited reconstruction of four NV- centers in (b) and (c). FWHM from left to right: 26 nm, 15 nm, 12 nm, and 46 nm, respectively. e. Full ESR spectrum of site with two centers. Colored lines indicate Lorentzian fits for each center with arrows indicating resonance frequencies at which images were taken for monitoring mode reconstruction with total acquisition time of 1.44s. f. Monitoring mode reconstruction of site in (b.) and (e.). The FWHM of centers from top to bottom are 53 nm and 24 nm.<\/p>\n"},"alt_text":"","media_type":"image","mime_type":"image\/jpeg","media_details":{"width":4498,"height":1582,"file":"2013\/07\/chen_nanodiamonds_02.jpg","sizes":{"thumbnail":{"file":"chen_nanodiamonds_02-150x150.jpg","width":150,"height":150,"mime_type":"image\/jpeg","source_url":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-content\/blogs.dir\/22\/files\/2013\/07\/chen_nanodiamonds_02-150x150.jpg"},"medium":{"file":"chen_nanodiamonds_02-300x105.jpg","width":300,"height":105,"mime_type":"image\/jpeg","source_url":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-content\/blogs.dir\/22\/files\/2013\/07\/chen_nanodiamonds_02-300x105.jpg"},"large":{"file":"chen_nanodiamonds_02-1024x360.jpg","width":1024,"height":360,"mime_type":"image\/jpeg","source_url":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-content\/blogs.dir\/22\/files\/2013\/07\/chen_nanodiamonds_02-1024x360.jpg"},"post-thumbnail":{"file":"chen_nanodiamonds_02-150x150.jpg","width":150,"height":150,"mime_type":"image\/jpeg","source_url":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-content\/blogs.dir\/22\/files\/2013\/07\/chen_nanodiamonds_02-150x150.jpg"},"abstract-thumb":{"file":"chen_nanodiamonds_02-220x77.jpg","width":220,"height":77,"mime_type":"image\/jpeg","source_url":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-content\/blogs.dir\/22\/files\/2013\/07\/chen_nanodiamonds_02-220x77.jpg"},"full":{"file":"chen_nanodiamonds_02.jpg","width":4498,"height":1582,"mime_type":"image\/jpeg","source_url":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-content\/blogs.dir\/22\/files\/2013\/07\/chen_nanodiamonds_02.jpg"}},"image_meta":{"aperture":0,"credit":"","camera":"","caption":"","created_timestamp":0,"copyright":"","focal_length":0,"iso":0,"shutter_speed":0,"title":""}},"post":1573,"source_url":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-content\/blogs.dir\/22\/files\/2013\/07\/chen_nanodiamonds_02.jpg","_links":{"self":[{"href":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-json\/wp\/v2\/media\/1576"}],"collection":[{"href":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-json\/wp\/v2\/media"}],"about":[{"href":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-json\/wp\/v2\/types\/attachment"}],"author":[{"embeddable":true,"href":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-json\/wp\/v2\/users\/370"}],"replies":[{"embeddable":true,"href":"https:\/\/mtlsites.mit.edu\/annual_reports\/2013\/wp-json\/wp\/v2\/comments?post=1576"}]}}